100 - 125Kva Generator Rental
Product & Services
- 7.5 – 15 KVA Generator
- 20 30 kva Generator
- 70 to 82.5 KVA
- 40 to 62.5 KVA
- 35 to 40KVA Generator
- 275 – 320kVA Generator on Rental
- 250kVA Generator Rental
- 380kVA Generator Rental Services
- 500 Generator Rental
- 600- 650kVA Generator Rental
- 100- 125kVA Generator Rental
- 750 – 810kVA Generator for Rent
- 1010kVA DG Set on Rent
- 1250 – 1500 kVA Generator on Rent
- 2000 – 2250kVA Generators for rent
- 2750kVA Generators for rent
- 7.5 – 15 KVA Generator
- 20 30 kva Generator
- 70 to 82.5 KVA
- 40 to 62.5 KVA
- 35 to 40KVA Generator
- 275 – 320kVA Generator on Rental
- 250kVA Generator Rental
- 380kVA Generator Rental Services
- 500 Generator Rental
- 600- 650kVA Generator Rental
- 100- 125kVA Generator Rental
- 750 – 810kVA Generator for Rent
- 1010kVA DG Set on Rent
- 1250 – 1500 kVA Generator on Rent
- 2000 – 2250kVA Generators for rent
- 2750kVA Generators for rent
100 - 125Kva Generator Rental
Latest Technology Product with Global Cummins® Platform
- The Cummins® QSL9 series heavy-duty engine and world class Stamford alternator powered diesel generator set
- Class defining Quantum engine technology with fully integrated subsystems
- Full Authority Electronic Engine
- Advanced in-cylinder technology to meet latest emission norms without any after-treatment device
- Smart aesthetic and superior finish
- Compact in size with optimum power to weight ratio
Environment Friendly Power
- Class defining technology engine is designed to meet stringent exhaust emission tests as per revised MoEF norms, thus offering environment friendly
- The Cummins® diesel generator sets are available with the lowest noise levels in its range
Lowest Operating Cost and Comprehensive Warranty
- Highly reliable and durable product
- All elements are designed to work together to maximize efficiency even at part loads, offering the advantage of lowest operating costs
- 500 Hours/ 1 year service interval
- Industry acknowledged best-in-class comprehensive warranty on the entire package including rubber components
Single Source Power Assurance
- All the major components – the engine, alternator, control system and canopy are designed, manufactured and tested by Cummins India
- Best and Largest customer support network in India, capable of providing round-the-clock service and spares support
- All these things put together, Cummins® offers you SINGLE SOURCE POWER ASSURANCE
Engine
- Cummins® QSL9 series, 6 cylinder, In-line 4 stroke, radiator cooled engine
- Full Authority Electronic Engine
- Well designed air handling system with
- Dry type, replaceable paper element air cleaner with restriction indicator
- Air to air aftercooling
- Optimised turbocharger for increased altitude capabilities
- Best in class fuel economy with
- Bosch HPCR fuel system with A1 class electronic governing
- Dual fuel filter system: Pre filter including water separator and Water In Fuel (WIF) sensor and main filter
- Electrical lift pump for faster response
- Standard integral set-mounted radiator system, designed and tested for 50°C ambient temperature
- Full flow spin on lube oil filter
- Plate type lube oil cooler
- First fill of lube oil and coolant
- Electrical starter motor with soft start engagement feature
- Battery charging alternator
- 2 x 12 V DC batteries
Alternator
- Stamford HC4 alternator frames from Cummins Generator Technologies
- Brushless type, Screen protected, Revolving field, Self excited alternator conforming to IS/IEC 60034-1
- 3 Phase reconnectable winding with 12 terminals brought out for connection
- Better motor starting capability
- Best in class efficiency
- Compact design with sealed bearings for longer life and lesser maintenance
- Impregnation on all wound components for better mechanical strength
Control Panel
Control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:
- PowerCommand®1 Controller
- Aluminum bus bars with suitable capacity with incoming/ outgoing terminals
- Indicating lamps for ‘Load ON’ and ‘Set Running’
- Instrument fuses duly wired and ferruled
- MCCB of suitable rating with overload and short circuit protections
PowerCommand 1.1 Features
The PowerCommand® control system is a microprocessor based generator set monitoring, metering and control system with LCD
display designed to meet the demands of today’s engine driven generator sets
- Intuitive operator interface which includes LED backlit LCD display with tactile feel soft-switches & generator set status LED lamps
- Digital AVR for shunt or PMG excitation with torque matching
- Digital electronic governing with temperature compensation and smart starting
- SAE J1939 interface to Full Authority Electronic (FAE) engines
- Remote start-stop
- Engine metering: Oil pressure, Coolant temperature, Battery voltage, Engine speed
- AC Alternator metering: L-L Voltage and L-N Voltage, Current (1 and 3 phase), Volt-Amperes (phase and total) and Frequency
- Engine protection: Low lube oil pressure, High/Low coolant temperature, Over speed, Battery Over/Under/Weak Volts, Fail to crank/start, Sensor failure
- AC Alternator protection: Over/Under voltage, Over/Under frequency, Over current, Short circuit and Loss of AC sensing
- Data logging: Engine hours, Control hours, Engine starts and upto 10 recent fault codes
- Configurable glow plug control
- Configurable cycle cranking
- 12 and 24 Volt DC operation
- Sleep mode
- Programmable I/Os (4 inputs and 2 outputs), expandable with AUX101/102 modules
- Modbus interface (RS485 RTU)
- InPower compatible (PC based service tool)
- Certifications – meets the requirement of relevant UL, NFPA, ISO, IEC, Mil , CE and CSA standards
Silencer
- Hospital grade silencer suitably optimised to meet stringent noise emission standards laid down by MoEF / CPCB
Mounting Arrangement
- Engine and alternator are mounted on a common MS fabricated base frame with AVM
- Base frame with integral fuel tank is provided with drain plug, air vent, inlet and outlet connection, level indicator and provision for cleaning
Optional
- Engine: Coolant heater, Oil drain pump, Heavy duty air cleaner
- Alternator: PMG
- Control Panel: 2, PC3.3, Microprocessor/ Relay based AMF control panel
- Others: Mobile sets with canopy
Acoustic Enclosure
- Specially designed to meet stringent MoEF/ CPCB norms of 75 dBA @ 1mtr at 75% load under free field conditions
- The acoustic enclosure is made of CRCA sheets in munsel green shade and a structural/ sheet metal base frame painted in black
- High quality noise absorbant and fire-retardant grade acoustic insulation material (Rockwool) complying to IS 8183
- Base lifting for easy handling at customer site
- Designed to have optimum serviceability
- Air inlet louvers specially designed to operate at rated load
- Made on special purpose CNC machines for consistency in quality and workmanship
- 11 tank pretreatment process and UV resistant powder coating of all parts to withstand extreme environment
- Use of special hardware for longer life
- Flush styling – no projections
- Fluid drains for lube oil and fuel
- Fuel filling arrangement inside the enclosure
Technical Data
Generator Set Specification
| Model | C100D5P | C125D5P |
| Duty | Prime | Prime |
| Power Rating kVA / kWe | 100/80 | 125/100 |
| No. of Phases | 3 | 3 |
| Output Voltage and Frequency (V and Hz) | 415 V, 50 Hz | 415 V, 50 Hz |
| Power Factor | 0.8 (lagging) | 0.8 (lagging) |
| Current (A) | 139 | 174 |
| RPM Engine specification | 1500 | 1500 |
| Make | Cummins | Cummins |
| Model | 6BTAA5.9-G13 | 6BTAA5.9-G13 |
| MoEF Certified Power (hp) | 159 | 159 |
| Required Power for Rated kVA (hp) | 129 | 158 |
| Cooling | Liquid Cooled (EG Compleat 50:50) | Liquid Cooled (EG Compleat 50:50) |
| Aspiration | Turbocharged, Charge Air Cooled | Turbocharged, Charge Air Cooled |
| No. of cylinders | 6, In-line | 6, In-line |
| Bore (mm) x Stroke (mm) | 102 x 120 | 102 x 120 |
| Compression ratio | 16.5:1 | 16.5:1 |
| Displacement (litre) | 5.9 | 5.9 |
| Fuel | High Speed Diesel | High Speed Diesel |
| Fuel consumption @75% load with radiator and fan* (litre/hr) | 18.4 | 22.4 |
| Fuel consumption @100% load with radiator and fan* (litre/hr) | 24.4 | 30.35 |
| Performance class of generator set | ISO 8528-5 G2 | ISO 8528-5 G2 |
| Starting system | 12 V DC Electrical | 12 V DC Electrical |
| Lube oil specification | CI4+ 15W40 | CI4+ 15W40 |
| Lube oil sump capacity, High-Low level (litre) | 19.9-14.9 | 19.9-14.9 |
| Total lubrication system capacity (litre) | 21.4 | 21.4 |
| Lube oil consumption @ full load** (litre/hr) | 0.024 | 0.024 |
| Total coolant capacity (litre) | 26 | 26 |
| Exhaust pipe size (inch) | 4 | 4 |
| Total wet weight (Engine+Radiator)## (kg) | 523 | 523 |
| Length x Width x Height (Engine) (mm) | 1066 x 725 x 1033 | 1066 x 725 x 1033 |
| Mean Piston speed (m/s) | 6 | 6 |
| Combustion air intake @100% load (±5%) (cfm) | 311 | 311 |
| Exhaust Temperature (°C) Alternator specification | 553 | 553 |
| Make | Stamford (CGT) | Stamford (CGT) |
| Alternator Frame | UCI274C | UCI274V |
| Enclosure | IP 23 | IP 23 |
| Voltage regulation (Max.) | ±1% | ±1% |
| Class of Insulation | H Class | H Class |
| Winding Pitch | 2/3 | 2/3 |
| Stator Winding | Double layer lap | Double layer lap |
| Rotor | Dynamically Balanced | Dynamically Balanced |
| Waveform distortion/ Total Harmonic Distortion | No load < 1.5 %, Non distorting balanced linear load < 5 % | No load < 1.5 %, Non distorting balanced linear load < 5 % |
| Maximum Unbalanced Load across phases# | less than or equal to 25% | less than or equal to 25% |
| Telephonic Harmonic factor | < 2% | < 2% |
| Genset Model | Rating (kVA) | Length (mm) | Width (mm) | Height (mm) | Wet Weight## (kg) | Standard Fuel tank Capacity (litre) |
| C100D5P | 100 | 4000 | 1150 | 1850 | 2200 | 290 |
| C125D5P | 125 | 4000 | 1150 | 1850 | 2200 | 290 |
Conformance Standards
- ISO 3046
- ISO 9001
- IS 13018
- IS/IEC 60034-1
- IS 1460
- ISO 8528