2750kVA Generator Rental

Product & Services

2750kVA Generator Rental

Description

This Cummins® Power Generation commercial generator set is a fully integrated power generation system, providing optimum performance, reliability, and versatility for stationary standby, prime power, and continuous duty applications.

 

Features

Cummins® heavy-duty engine – Rugged 4-cycle industrial diesel delivers reliable power, low emissions and fast response to load changes.

Permanent magnet generator (PMG) – Offers enhanced motor starting and fault clearing short circuit capability.

Alternator – Several alternator sizes offer selectable motor starting capability with low reactance 2/3 pitch windings; low waveform distortion with non-linear loads, fault clearing short-circuits capability, and class F or H

insulation.

Cooling system – Optional remote mounted cooling system, designed and tested for rated ambient temperatures, offers maximum flexibility for facility design requirements.

Control system – Standard PowerCommand® electronic control provides total system integration including remote start/stop, precise frequency and voltage regulation, alarm and status message display, Amp Sentry protection, output metering, auto-shutdown.

Warranty – Backed by a comprehensive warranty and worldwide distributor network.

Generator set specifications 

Governor regulation ISO 8528 G2
Steady state voltage regulation, no load to full load ± 0.25%
Steady state frequency variation ± 0.25%
Frequency regulation Isochronous
EMC compatibility Radiated emissions to BS EN 61000-6.3 Conducted immunity to BS EN 61000-6.2
Engine specifications  
Design 4 cycle, V, turbo charged and low temperature after-cooled
Bore 170
Stroke 190
Displacement 77.6 L (4735 in3)
Cylinder block Cast iron, 18 cylinder
Battery capacity 2200 amps
Battery charging alternator 55 amps
Starting voltage 24-volt, negative ground
Fuel system Direct injection: number 2 diesel fuel, fuel filter, automatic electric fuel shutoff
Fuel filter Triple element, 10 micron filtration, spin on fuel filter with water separator
Air cleaner type Dry replaceable element
Lube oil filter type(s) Four spin-on, combination full flow and bypass filters
Cooling system 104 ºF (40 ºC) ambient

Alternator specifications

 
Design Brushless, 4 pole, drip-proof revolving field
Stator 2/3 pitch
Rotor 2 bearing, flexible coupling
Insulation system Class H on low and medium voltage, Class F on high voltage
Standard temperature rise 150 °C standby
Exciter type PMG (Permanent magnet generator)
Phase rotation A (U), B (V), C (W)
Alternator cooling Direct drive centrifugal blower fan
AC waveform total harmonic distortion No load <1.5%. Non distorting balanced linear load <3%
Telephone influence factor (TIF) < 50 per NEMA MG1-22.43
Telephone harmonic factor (THF) < 2%

Power Command® 3.3 control system

 Control system

The Power Command® control system is an integrated microprocessor based generator set control system providing voltage regulation, engine protection, alternator protection, operator interface and isochronous governing.

AmpSentry – Includes integral AmpSentry protection, which provides a full range of alternator protection functions that are matched to the alternator provided. Power management – Control function provides battery monitoring and testing features and smart starting control system.

Advanced control methodology – Three phase sensing, full wave rectified voltage regulation, with a PWM output for stable operation with all load types. Communications interface – Control comes standard with PCCNet and Modbus interface.

Regulation compliant – Prototype tested: UL, CSA and CE compliant.

Service – InPower™ PC-based service tool available for detailed diagnostics, setup, data logging and fault simulation.

Reliable design – The control system is designed for reliable operation in harsh environment.

Multi-language support

Operator panel features

Operator panel features – The operator panel, in addition to the alternator, displays the Utility/AC Bus data.

Operator/display functions

  • 320 x 240 pixels graphic LED backlight LCD
  • Auto, manual, start, stop, fault reset and lamp test/panel lamp switches
  • Alpha-numeric display with pushbuttons
  • LED lamps indicating genset running, remote start, not in auto, common shutdown, common warning, manual run mode, auto mode and stop

Paralleling control functions

  • Digital frequency synchronization and voltage matching
  • Isochronous kW and kvar load sharing controls
  • Droop kW and kvar control
  • Sync check
  • Extended paralleling (Peak Shave/Base Load)
  • Digital power transfer control (AMF) provides load transfer operation in open or closed transition or soft (ramping) transfer mode

Alternator data

  • Line-to-neutral and line-to-line AC volts
  • 3-phase AC current
  • Frequency
  • kW, kvar, power factor kVA (three phase and total)

Engine data

  • DC voltage
  • Engine speed
  • Lube oil pressure and temperature
  • Coolant temperature
  • Comprehensive FAE data (where applicable)

Other data

  • Genset model data
  • Start attempts, starts, running hours, kW hours
  • Load profile (operating hours at % load in 5% increments)
  • Fault history
  • Data logging and fault simulation (requires InPower)

Standard control functions

Digital governing (optional)

  • Integrated digital electronic isochronous governor
  • Temperature dynamic governing

Digital voltage regulation

  • Integrated digital electronic voltage regulator
  • 3-phase, 4-wire line-to-line sensing
  • Configurable torque matching

AmpSentry AC protection

  • AmpSentry protective relay
  • Over current and short circuit shutdown
  • Over current warning
  • Single and three phase fault regulation
  • Over and under voltage shutdown
  • Over and under frequency shutdown
  • Overload warning with alarm contact
  • Reverse power and reverse var shutdown
  • Field overload
Engine protection
  • Battery voltage monitoring, protection and testing
  • Over speed shutdown
  • Low oil pressure warning and shutdown
  • High coolant temperature warning and shutdown
  • Low coolant level warning or shutdown
  • Low coolant temperature warning
  • Fail to start (over crank) shutdown
  • Fail to crank shutdown
  • Cranking lockout
  • Sensor failure indication
  • Low fuel level warning or shutdown
  • Fuel-in-rupture-basin warning or shutdown
  • Full authority electronic engine protection

Control functions

  • Time delay start and cool down
  • Real time clock for fault and event time stamping
  • Exerciser clock and time of day start/stop
  • Data logging
  • Cycle cranking
  • Load shed
  • Configurable inputs and outputs (4)
  • Remote emergency stop

Options

  • Auxiliary output relays (2)

Emergency standby power (ESP):

Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. Emergency Standby Power (ESP) is in accordance with ISO 8528. Fuel Stop power in accordance with ISO 3046, AS 2789, DIN 6271 and

BS 5514.

Limited-time running power (LTP):

Applicable for supplying power to a constant electrical load for limited hours. Limited Time Running Power (LTP) is in accordance with ISO 8528.

Prime power (PRP):

Applicable for supplying power to varying electrical load for unlimited hours. Prime Power (PRP) is in accordance with ISO 8528. Ten percent overload capability is available in accordance with ISO 3046, AS 2789, DIN 6271 and BS 5514.

Base load (continuous) power (COP):

Applicable for supplying power continuously to a constant electrical load for unlimited hours. Continuous Power (COP) in accordance with ISO 8528, ISO 3046, AS 2789, DIN 6271 and BS 5514.

 

This outline drawing is to provide representative configuration details for Model series only.

 

See respective model data sheet for specific model outline drawing number.                  Do not use for installation design

Conformance  Standards

Scroll to Top
Get More Information