1250 - 1500 kVA Generator on Rent
Product & Services
- 7.5 – 15 KVA Generator
- 20 30 kva Generator
- 70 to 82.5 KVA
- 40 to 62.5 KVA
- 35 to 40KVA Generator
- 275 – 320kVA Generator on Rental
- 250kVA Generator Rental
- 380kVA Generator Rental Services
- 500 Generator Rental
- 600- 650kVA Generator Rental
- 100- 125kVA Generator Rental
- 750 – 810kVA Generator for Rent
- 1010kVA DG Set on Rent
- 1250 – 1500 kVA Generator on Rent
- 2000 – 2250kVA Generators for rent
- 2750kVA Generators for rent
- 7.5 – 15 KVA Generator
- 20 30 kva Generator
- 70 to 82.5 KVA
- 40 to 62.5 KVA
- 35 to 40KVA Generator
- 275 – 320kVA Generator on Rental
- 250kVA Generator Rental
- 380kVA Generator Rental Services
- 500 Generator Rental
- 600- 650kVA Generator Rental
- 100- 125kVA Generator Rental
- 750 – 810kVA Generator for Rent
- 1010kVA DG Set on Rent
- 1250 – 1500 kVA Generator on Rent
- 2000 – 2250kVA Generators for rent
- 2750kVA Generators for rent
1250 - 1500 kVA Generator on Rent
Reliable and durable
Cummins® ‘K50 series’ diesel engine with strong regrindable crankshaft, high strength connecting rod, low pressure fuel lines, STC (Step Timing Controls) injectors and high volume coolant system make ‘K50 series’ generating sets, more reliable and durable. Engines have clocked millions of hours operating in some of the world’s most demanding conditions. Current engines are regularly upgraded with new technologies for better performance and economy. The ultimate proof of superior performance and reliability is the fact that Cummins® entities worldwide source these engines from Cummins India for their markets.
Unmatched warranty
- Cummins® ‘K50 series’ diesel engine generating sets are a truly cost effective solution
to long term power need backed by industry best, 2 years / 5000 hrs warranty, for the entire generating set.
- With superior experience in technology, design capability and commitment reliability and quality we offer an unmatched 5 years or 5000 hours (including above 2 years) warranty coverage on 5 critical components (5C) of the
engine – Cylinder Head, Camshaft, Crankshaft, Cylinder Block, Connecting Rod against manufacturing defect
Cummins advantage
Special features of Cummins® ‘K50 series’ engines like STC (Step Timing Controls) injectors, low temperature aftercooler, square cumbustion chamber, optimised turbocharging and precision heavy duty camshaft make these engines the ultimate in exceptional fuel efficiency all across the operating range.
Single source power assurance
Design, manufacture and testing of engine, alternator and other accessories is done by Cummins Group of companies for optimum performance and is backed by a countrywide product support network with a single source responsibility for the entire package.
Standard scope
Engine: Cummins® ‘K50 series’ direct injection, water cooled engine, 16 cylinder, 4 stroke, rated at 1500 RPM, conforming to ISO 3046 / IS 13018 has the following specifications:
- Cummins PT fuel pump
- Cummins heavy duty ESTC injectors
- Holset turbocharger, pulse tuned exhaust manifold, stainless steel exhaust flexible connections
- Radiator or heat exchanger, coolant inhibitor
- Plate type lube oil cooler
- Outboard aftercoolers
- Full flow paper element filters – fuel, lube oil and by-pass
- Dry type replaceable paper element air cleaner with restriction indicator
- Flywheel housing & flywheel to suit single/ double bearing
alternator
- Holset flexible coupling for double bearing alternator
- Starting motor – Electric, battery charging alternator
- Cummins PowerCommand® microprocessor based genset controller
- First fill lube oil and coolant
Alternator: Stamford brushless alternator
- Seperately excited, self-regulated – Class ‘H’ insulation
- Salient pole revolving field
- Single bearing
- PMG standard
– Space heater & RTD & BTD’s only sensor – (without scanner)
Accessories:
- Silencer suitably optimized to reduce noise
- Sturdy base rail
- 990 free standing fuel tank
- 4 x 12 V dry, uncharged batteries with connecting leads and terminals
Optionals
Engine: Heavy duty air cleaner, Lube oil / Coolant heater with thermostatic switch
Alternator: Double bearing
Control Panel: AMF control panel, Battery charger, Remote/Auto start panel, Auto/Manual synchronizing panel, Audio/Visual annunciation for faults
Control panel: PowerCommand® PC 3.3
The PowerCommand® control system is an integrated microprocessor based generator set control system providing voltage regulation, engine protection, alternator protection, operator interface and isochronous governing.
AmpSentry – Includes integral AmpSentry protection, which provides a full range of alternator protection function which are matched to the alternator provided.
Power management – Control function provides battery monitoring, testing and a smart starting control system.
Advanced control methodology – Three phase sensing, FET based full wave rectified voltage regulation and a PWM output for stable operation with all load types.
Communications interface – Control comes standard with PCCNet and Modbus interface.
Regulation compliant – Prototype tested: UL, CSA and CE compliant.
Service – InPower™ PC-based service tool available for detailed diagnostics, setup, data logging and fault simulation.
Reliable design – For reliable operations in harsh environment.
Multi-language support
Independent of PC/ laptop for setting up
Operator panel features
Operator panel features – The operator panel, in addition to the alternator, displays the Utility/ AC Bus data.
Operator/ display functions
- 320 x 240 pixels graphic LED backlight LCD with bar graph for displaying electrical parameters
- Auto, manual, start, stop, fault reset and lamp test/panel lamp switches
- Alpha-numeric display with pushbuttons
- LED lamps indicating genset running, remote start, not in auto, common shutdown, common warning, manual run mode, auto mode and stop
Paralleling control functions
- Digital frequency synchronization and voltage matching
- Isochronous kW and kvar load sharing controls
- Droop kW and kvar control
- Sync check
- Extended paralleling (Peak Shave/Base Load)
- Digital power transfer control (AMF) provides load transfer operation in open or closed transition or soft (ramping) transfer mode
Alternator data
- Line-to-neutral and line-to-line AC volts
- 3-phase AC current
- Frequency
- kW, kvar, power factor kVA (three phase and total)
Engine data
- DC voltage
- Engine speed
- Lube oil pressure
- Coolant temperature/ low level
- Comprehensive FAE data (where applicable)
Other data
- Genset model data
- Start attempts, starts, running hours, kW hours
- Load profile (operating hours at % load in 5% increments)
- Fault history
- Data logging and fault simulation (requires InPower)
Standard control functions
Digital governing
- Integrated digital electronic isochronous governor
- Temperature dynamic governing
Digital voltage regulation
- Integrated digital electronic voltage regulator
- 3-phase, 4-wire line-to-line sensing
- Configurable torque matching
AmpSentry AC protection
- AmpSentry protective relay
- Over current and short circuit shutdown
- Over current warning
- Single and three phase fault regulation
- Over and under voltage shutdown
- Over and under frequency shutdown
- Overload warning with alarm contact
- Reverse power and reverse var shutdown
- Field overload
Engine protection
- Battery voltage monitoring, protection and testing
- Over speed shutdown
- Low oil pressure warning and shutdown
- High coolant temperature warning and shutdown
- Low coolant level warning or shutdown
- Low coolant temperature warning
- Fail to start (over crank) shutdown
- Fail to crank shutdown
- Cranking lockout
- Sensor failure indication
- Low fuel level warning or shutdown
Control functions
- Time delay start and cool down
- Real time clock for fault and event time stamping
- Exerciser clock and time of day start/stop
- Data logging
- Cycle cranking
- Load shed/ dump as per configurable priority
- Configurable inputs and outputs (4)
- Remote emergency stop
Options
- Auxiliary output relays and remote annunciators
Generator set specifications
| Model | C750D5P | C810D5P |
| Duty | Prime | Prime |
| Power Rating kVA / kWe | 750/600 | 810/648 |
| No. of Phases | 3 | 3 |
| Output Voltage and Frequency (V and Hz) | 415 V, 50 Hz | 415 V, 50 Hz |
| Power Factor | 0.8 (lagging) | 0.8 (lagging) |
| Current (A) | 1043 | 1126 |
| RPM | 1500 | 1500 |
Engine Specification
| Make | Cummins | Cummins |
| Model | KTA38-G12 | KTA38-G12 |
| MoEF Certified Power (hp) | 1069 | 1069 |
| Required Power for Rated kVA (hp) | 891 | 960 |
| Cooling | Liquid cooled (Distilled Water +DCA2) | Liquid cooled (Distilled Water +DCA2) |
| Aspiration | Turbocharged Aftercooled | Turbocharged Aftercooled |
| No. of cylinders | 12, Vee | 12, Vee |
| Bore (mm) x Stroke (mm) | 159 x 159 | 159 x 159 |
| Compression ratio | 16.7:1 | 16.7:1 |
| Displacement (litre) | 38 | 38 |
| Fuel | High Speed Diesel | High Speed Diesel |
Fuel consumption @75% load with radiator and fan* (litre/hr) | 130.50 | 138.94 |
Fuel consumption @100% load with radiator and fan* (litre/hr) | 166.32 | 177.41 |
| Performance class of generator set | ISO 8528-5 G2 | ISO 8528-5 G2 |
| Starting system | 24 V DC Electrical | 24 V DC Electrical |
| Lube oil specification | CH4 15W40 | CH4 15W40 |
Lube oil sump capacity, High-Low level (litre) | 140 – 114 | 140 – 114 |
| Total lubrication system capacity (litre) | 155 | 155 |
| Total coolant capacity (litre) | 330 | 330 |
| No. of banks x Exhaust pipe size (inch) | 2 x 8 | 2 x 8 |
| Total wet weight (Engine+Radiator)## (kg) | 5800 | 5800 |
| Length x Width x Height (Engine) (mm) | 2269 x 1436 x 1764 | 2269 x 1436 x 1764 |
| Mean piston speed (m/s) | 7.95 | 7.95 |
Combustion air intake @100% load (±5%) (cfm) | 2011 | 2103 |
| Exhaust Temperature (°C) | 520 | 521 |
Alternator Speci ication
| Make | Stamford (CGT) | Stamford (CGT) |
| Alternator frame | HCI634W | HCI634V |
| Enclosure | IP 23 | IP 23 |
| Voltage regulation (Max.) | ±1% | ±1% |
| Class of Insulation | H Class | H Class |
| Winding Pitch | 2/3 | 2/3 |
| Stator Winding | Double layer lap | Double layer lap |
| Rotor | Dynamically Balanced | Dynamically Balanced |
Waveform distortion/ Total Harmonic Distortion | No load < 1.5 %, Non distorting balanced linear load < 5 % | No load < 1.5 , Non distorting balanced linear load < 5 % |
| Maximum Unbalanced Load across phases# | less than or equal to 25% | less than or equal to 25% |
| Telephonic Harmonic factor | < 2% | < 2% |
| Genset Model | Rating (kVA) | Length (mm) | Width (mm) | Height (mm) | Wet Weight## (kg) | Standard Fuel tank Capacity (litre) |
| C750D5P | 750 | 8000 | 2600 | 3000 | 11900 | 990 |
| C810D5P | 810 | 8000 | 2600 | 3000 | 11900 | 990 |